HRB Trigger and Timing Control
Used in: HRB128E, HRB6ASD, TTB6, TTB9V
Electrical
Signal levels: LVDS, transformer coupled
Physical Coding Sublayer
Serial encoding 8B10B, LSB first. Comma (K28.5) symbol sequence is used for bit synchronization and inter-frame fill. HRB TTC Data Format
Mechanical
Connector type: 8P8C (RJ45), TIA/EIA 568B Standard
Cable: Category 6a
Connector and Signals
pin |
TIA/EIA 568B |
Pair |
Signal |
1 |
white/orange |
TR2- |
RESET- |
2 |
orange |
TR2+ |
RESET+ |
3 |
white/green |
TR3- |
CLK- |
4 |
blue |
TR1+ |
TRIG+ |
5 |
white/blue |
TR1- |
TRIG- |
6 |
green |
TR3+ |
CLK+ |
7 |
white/brown |
TR4- |
BUSY- |
8 |
brown |
TR4+ |
BUSY+ |