HRB Trigger and Timing Control

Used in: HRB128E, HRB6ASD, TTB6, TTB9V

Electrical

Signal levels: LVDS, transformer coupled

Physical Coding Sublayer

Serial encoding 8B10B, LSB first. Comma (K28.5) symbol sequence is used for bit synchronization and inter-frame fill. HRB TTC Data Format

Mechanical

Connector type: 8P8C (RJ45), TIA/EIA 568B Standard

Cable: Category 6a


Connector and Signals

pin

TIA/EIA 568B

Pair

Signal

1

white/orange

TR2-

RESET-

2

orange

TR2+

RESET+

3

white/green

TR3-

CLK-

4

blue

TR1+

TRIG+

5

white/blue

TR1-

TRIG-

6

green

TR3+

CLK+

7

white/brown

TR4-

BUSY-

8

brown

TR4+

BUSY+

tia568b.png


HRB TTC

HRB_TTC (last edited 2015-04-08 13:46:41 by sav)