Spill Control Module

Register Map

address space 0x00 - 0x3F

addr

bits

description

mode

default

00h

32

spill phase 1 (idle) duration, ms

R/W

10

02h

32

spill phase 2 (pre-burst triggers) duration

R/W

10

04h

32

spill phase 3 (burst triggers) duration

R/W

3000

06h

32

spill phase 4 (post-burst triggers) duration

R/W

10

08h

32

spill phase 5 (software readout) duration

R/W

970

0Ah

32

spill gate extension

R/W

100

0Ch

32

spill count (locked)

RO

0Eh

32

current spill timer value, ms

RO

10h

32

spill control

R/W

0

12h

32

spill status

RO

14h

32

spill timer period, ms

R/W

5000

16h

32

spill detect min period, ms

R/W

1000

18h

32

spill detect max period, ms

R/W

30000

1Ah

32

measured last TTL spill period, ms

RO

1Ch

32

measured last WR spill period, ms

RO

1Eh

reserved

20h

64

last spill TAI timestamp (locked)

RO

24h

reserved

...

3Fh

Reg 0x10, spill control, R/W

Reg 0x12, spill status, RO

Spill phases:

Reg 0x20, last spill TAI timestamp


SDB

Spill Control Module (last edited 2023-07-28 08:55:51 by filippov)