= TADC Run Statistic Counters = '''Base address - 0x0700, address mask - 0x00FF.''' Every register is 64 bits width. Actual counters width is 48 bits. ||<:> '''Counter''' ||<:> '''Address''' ||<:> '''Description''' ||<:> '''Type''' ||<:> '''Option''' || ||<:> 1 ||<:> 0x0000 || Run Uptime || Level || Run || ||<:> 2 ||<:> 0x0004 || LEMO Input Pulse Count || Edge || Total || ||<:> 3 ||<:> 0x0008 || TTC Input Pulse Count || Edge || Total || ||<:> 4 ||<:> 0x000C || VXS Input Pulse Count || Edge || Total || ||<:> 5 ||<:> 0x0010 || Reserved (FELink) || n/a || n/a || ||<:> 6 ||<:> 0x0014 || Trigger Candidates || Edge || Run || ||<:> 7 ||<:> 0x0018 || Accepted Triggers || Edge || Run || ||<:> 8 ||<:> 0x001C || Blocked Triggers || Edge || Run || ||<:> 9 ||<:> 0x0020 ||<|3> Reserved || n/a || n/a || ||<:> ...||<:> ... || ... || ... || ||<:> 16 ||<:> 0x003C || n/a || n/a || ||<:> 17 ||<:> 0x0040 || Total Busy Time || Level || Run || ||<:> 18 ||<:> 0x0044 || ADC Busy Time || Level || Run || ||<:> 19 ||<:> 0x0048 || TDC Busy Time || Level || Run || ||<:> 20 ||<:> 0x004C || Readout Busy Time || Level || Run || ---- [[CategoryMlinkRegisters|MLinkRegisters]]