= TADC Run Logic Registers = '''Base address - 0x0060, address mask - 0x001F.''' Reg 0, @0x0000 - Run Mode, R/W . all bits are '0' - normal mode, run stops from software . [0] - time limit mode . [1] - event number limit mode Reg 1, @0x0001 - Run State, RO . [0] - '1' run is active, '0' not in run Reg 2, @0x0002 - reserved Reg 3, @0x0003 - reserved Reg 4, @0x0004 - run start time code in TAI (64 bits), RO . [63:32] - seconds since Epoch . [31:2] - nanoseconds . [1:0] - flags: 2 - time valid, others - time invalid Reg 5, @0x0008 - run time limit in milliseconds (32 bits), R/W Reg 6, @0x000A - run event number limit (32 bits), R/W ---- [[CategoryMlinkRegisters|MLinkRegisters]]