## page was renamed from TADC Run Logic === Run Logic === * [[SDB Device ID]] 0xf4da37e8 ==== Register Map ==== * 0x00, Identification ''f4da37e8'', 32 bits, RO * 0x02, Control, R/W * [0] - softclear * [14:1] - reserved * [15] - softrun * 0x03, Counters lock, R/W * [0] - counters lock * [15:1] - reserved * 0x04, Run Mode, R/W * all bits are '0' - normal mode, run stops from software * [0] - time limit mode * [1] - event count limit mode * 0x05, Run State, RO * [0] - '1' run is active, '0' not in run * [1] - run finished by either limit condition * 0x06, Run time limit in milliseconds, 32 bits, R/W * 0x08, Run event count limit, 32 bits, R/W * 0x0A, Current event count, 32 bits, RO * 0x10, Run start time, [[TAI 64-bit Timestamp|TAI]], RO * 0x14, Run stop time, [[TAI 64-bit Timestamp|TAI]], RO * 0x18, Current time, [[TAI 64-bit Timestamp|TAI]], RO * 0x1C, Run time in milliseconds, 32 bits, RO ---- [[CategorySDB|SDB]]