PCOS-II Module Registers

Hardware: PCOS2

Registers are 16 bit width. 32-bit and 64-bit data is packed as following:

Reg #

64-bit word

0x70

bits 15:0

0x71

bits 31:16

0x72

bits 47:32

0x73

bits 63:48

Register I/O

Reg 0x40, Control, R/W

Reg 0x42, Device ID, RO

Reg 0x43, Factory Test, R/W

Reg 0x47, Branch #1 Status, RO

Reg 0x48, Branch #2 Status, RO

Reg 0x49, PCOS-II branches clock period, default 200 ns (0x000A), step 20 ns, R/W

Reg 0x4A, Test Word sent to branches, 32-bit, R/W

Reg 0x4C, Settings, R/W

Reg 0x50, 64-bit Board Serial Number (DS18B20), RO

Reg 0x54, current temperature, RO

Reg 0x55, reserved, RO

Reg 0x56, 16-bit, firmware version number, RO

Reg 0x57, 16-bit, firmware revision number, RO

Reg 0x5A link status, RO

Reg 0x100 ... 0x13F - Branch #1 Data, RO

Reg 0x200 ... 0x23F - Branch #2 Data, RO

OUTDATED

Reg 0x58 ... 5D, Link statistics, RO

Reg 0x61 - Link status, RO


BRICBOX MLinkRegisters